Dear Customer, Thank you for choosing the BRAVO 12 inflator manometer.
This device has been designed specifically to inflate/deflate dinghies up to 5/6 metres and all kites on the market.
 
WARNINGS

- Before connecting the terminals to the battery, check that the voltage is the same as shown on the label.
- It is forbidden to use the device in humid environments and/or close to water..
- Keep the product out of the reach of children.
- Do not leave the inflator running unattended.
- Do not use the inflator with adapters other than those supplied with the product as they could damage the device.
- Repairs must only be undertaken by an authorized customer technical service
  Scoprega S.p.a. – Ningbo Bravo.
- The manufacturer is not responsible for damage caused as a result of improper use or failure to observe the envisaged usage.

Long periods of use can cause overheating and damage the product.
Do not use for more than 20 minutes continuously.

INFLATION OPERATION

1 From the supplied fittings, select the reducer that engages and opens the valve of the inflatable structure.
2 Insert the selected adaptor on the braided joint on the end of the tube.
3 Turn the ring nut on the manometer and point the arrow to the required pressure.
4 Tighten the adaptor onto the inflation side of the inflator (OUT).
5 Connect the terminals paying attention to the polarity and press the (ON) button to start inflation.
6 The inflator operates in two stages which can be identified by the noise of the turbine at the beginning followed by the piston. The inflator switches from turbine to piston automatically.
7 Once the entered pressure has been reached, the inflator turns off automatically.
It is possible to stop the inflator at any time by pressing the (OFF) switch.

ATTENTION: When the device is under pressure, never turn the ring nut on the manometer anti-clockwise as this would immediately cause the instrument to break.
Protect the inflator from sand by keeping it in the bag provided: if sand gets into the inflator, it could get JAMMED.

DEFLATING OPERATION 1/2

As above.
3 Tighten the adaptor on to the deflation side of the inflator (IN).
4 Connect the terminals and press the (ON) button to start deflation.
5 THE INFLATOR DOES NOT TURN OFF AUTOMATICALLY!!!
When the inflatable is completely deflated, switch OFF the inflator immediately to avoid overheating the motor.

SAND FILTER MAINTENANCE

The inflator has a filter compartment under the inflation chuck (IN).
- We recommend to keep them clean for the inflator to be longer lasting and more effective.
- Loosen the two screws blocking the inflation chuck (IN).
- Lift the chuck and take it off.
- Clean with compressed air or replace if it is too dirty.

WARRANTY

The inflator is guaranteed for 2 years.

In case of claims do not touch the device and send it free-destination to Scoprega S.p.a. – Ningbo Bravo or directly to the seller.

BACK TO BRAVO PUMPS PAGE
 

TOP

Dealers, Lodges, Guides contact Dave for Water Strider's Wholesalers Program.

 
dave@waterstrider.com

or call 406 375-0251

 

 


The Water Strider web is:
Official PayPal Seal
 

Water Strider | 263 Three Pond Drive | Hamilton, Montana 59840
phone and fax 406.375.0251 | contact Water Strider

All content © Copyright 2005-2012. All rights reserved.  Sitemap | Privacy Policy | Terms Of Use
Last Updated Monday, April 30, 2012 | Web Services by Ron Castle Webs